of agreement. However, discrepancies in rotation correction were observed: although there was only small bias, there were relatively wide limits of agreement (no less than +/-0.6 o ). Conclusion The results presented confirmed only a minority of fractions required patient repositioning after the initial 2DkV. Removing this from the standard 3-step IGPBT process and streamlining to a 2-step workflow (commencing with CBCT) would reduce imaging dose and treatment times, thus improving efficiency and overall service capacity. The 2-step IGPBT workflow has now been implemented at our PBT Centre and is standard verification protocol. For challenging cases (e.g. paediatric patients under GA) further investigations are required before the 3-step workflow can be modified. PD-0069 Use of prescription isodose boundary to optimise treatment delivery during MR-guided Radiotherapy C. Votta 1 , D. Cusumano 1 , L. Boldrini 1 , V. Pollutri 1 , L. Placidi 1 , G. Chiloiro 1 , A. Romano 1 , M.V. Antonelli 1 , V. Valentini 1 1 Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Dipartimento di Diagnostica per Immagini- Radioterapia Oncologica ed Ematologia, Roma, Italy Purpose or Objective With the introduction of Magnetic Resonance-guided Radiotherapy (MRgRT), non-invasive continuous and direct monitoring of targets and organs at risk (OAR) during treatment delivery has become available. The gating strategy adopted in low tesla MRgRT systems consists in acquiring 4 MR images/second on a sagittal plan and stopping the radiation beam each time that the target structure moves beyond a boundary region pre-defined by the user. In clinical practice, the GTV is generally considered as target structure and PTV as boundary. This approach can lead to different criticalities, especially when treatment plans with inhomogeneous doses and low conformity are delivered. Aim of this study is to investigate the feasibility of using the prescription isodose volume (PIV) as boundary to optimise treatment delivery during MRgRT. Material and Methods A total of 31 patients (8 Lung, 15 Liver, 8 Pancreas) treated with MRgRT were retrospectively selected. For lesions larger than 2 cc, the Paddick conformity index (PCI) of the dose distribution and 2 boundaries were considered : a geometric one equal to PTV and a dosimetric one equal to PIV. The areas of the 2 boundaries (A GEO and A DOS ) were measured on the sagittal MR image passing through the GTV centre of mass. The comparison between the 2 boundaries was carried in terms of difference of boundary area and spatial displacement. The variation in terms of boundary area was measured as A DOS - A GEO . The spatial displacement between the 2 boundaries was evaluated as the distance between the centres of mass of the two areas (D com ) in anteroposterior (AP) and craniocaudal (CC) directions. Results The treatment plans of lung and liver lesions showed higher conformity than those related to pancreatic lesions (Mean PCI was 0.76 ±0.07 for Lung, 0.77 ±0.07 for Liver and 0.69 ±0.06 for pancreas). Figure 1 shows the spatial displacement of the two boundaries for all the patients analysed. For treatment plans with high dose conformity (lung and liver), no significant spatial displacement was observed between the two boundaries (D com <1mm for 91% of cases). Using the dosimetric boundary in such cases leads to an increase of boundary area of +22%, speeding up the treatment. For treatments with lower dose conformity (pancreas), a limited increase of boundary area was found (+2%).

However, a significant displacement between the two boundary areas was observed (mean D com = 2.3 ± 0.7 mm), mainly due to the presence of surrounding OARs, such as stomach or duodenum (fig.2). The displacement is mostly located in cranial (+1.1± 1.3 mm) and posterior direction (-1.4 ± 1.1 mm). Fig.1

Fig. 2

Conclusion The use of dosimetric boundaries in MRgRT could improve treatment efficiency and efficacy. This approach ensures a more reliable GTV coverage and may present further advantages in terms of delivery time reduction. PD-0070 Contour propagation for online treatment of rectal cancer using MR guidance A. Adams 1 , A. Betgen 1 , T. Vijlbrief 1 , B. Van Triest 1 , P. Remeijer 1 , T. Jansen 1 , J. Sonke 1 1 Netherlands Cancer Institute, Radiation Oncology, Amsterdam, The Netherlands Purpose or Objective Accurate registration and propagation of organ/tumor contours during online treatment plan adaptation is highly desirable within the paradigm of IGART as it allows faster, more consistent treatments over dose fractions.

Made with FlippingBook - Online magazine maker