IMRT Dose Calculation

• The fluence maps are generated at the time of optimisation

• The leaf motion is then calculated to enable the delivery of this

• The 3D dose calculation is then carried out generating a dose distribution

• Note the subtle changes: 

Fluence now reflected the deliverable values

The DVH is now based on AAA as opposed to PBC

Additional Contouring

Contouring

Field Setup

Plan Evaluation

Dose Calculation

Optimisation