Cervix BT - 2016
Evaluation / Reporting
Level 1 Minimum standard for reporting
HDR Absorbed Dose (Gy) Fraction size (Gy) Number of Fractions Interval between fr. (h)
LDR Absorbed Dose (Gy) Dose Rate (Gy/h) Number of Fractions and Treatment-time
PDR Absorbed Dose (Gy) Pulse size (Gy) Number of pulses, and interval between pulses Number of fractions and interval between fr.
Dose delivery pattern
Source and Dose calculation ( Radionuclide, Source model, Source Strength, Dose calculation algorithm ) Total treatment-time (TT) in hours or days of EBRT, BT and overall TT
Level 2 Advanced standard for reporting
Biological dose reporting
EQD2 values for traget and OAR (endpoints) Respective α/β values* for the target and OAR Respective T1/2 of recovery* Applied recovery model, mono- or bi-exponential
Level 3 Research oriented reporting
EUD or other biologically effective dose model calc. for target and OAR endpoints
TCP or NTCP calculation, with the model explicitly stated
*For the moment - advise to follow GEC-ESTRO recommendations α/β =3Gy for late Effects in OAR and 10 Gy for tumour response, and T 1/2 of 1.5h for both.