Dose 2016

A typical linac of today

3

Varian Clinac ® Engineered for Clinical Benefits

4

6

1 Gridded Electron Gun Controlsdose rate rapidly and accurately.Permits precise beam control for dynamic treatments, since gun can be gated. Removable for cost-effective replacement. 2 Energy Switch Patented switch provides energies within the full therapeutic range,at consistently high, stable dose rates, even with low energy x-ray beams. Ensures optimum performance and spectral purity at both energies. 3 Wave Guide High efficiency,side coupled standingwave accelerator guide with demountable electron gun and energy switch. 4 Achromatic 3-Field Bending Magnet Unique design with fixed ± 3 %energy slits ensures exact replication of the input beam for every treatment. The 270 o bendingsystem, coupled withVarian’s3-dimensional servo system, provides for a2 mm circular focal spot size for optimal portal imaging. 5 Real-Time Beam Control Steering System Radial and transverse steeringcoils and a real-time feedback system ensure that beam symmetry iswithin ± 2 %at all gantr y angles. Even at maximum dose rate – and any gantry angle – the circular focal spot remains less than 2 mm, held constant by a focus solenoid. Assuresoptimum image quality for portal imaging. 7 10-Port Carousel New electron scattering foils provide homogeneous electron beams at therapeutic depths. Extraports allow for future development of specialized beams. 8 Ion Chamber Dual sealed ion chambers with 8 sectors for rigourousbeam control provide two independent channels, impervious to changes in temperature and pressure.Beam dosimetry is monitored to be within ± 2 %for longterm consistency and stability. 9 Asymmetric Jaws Four independent collimatorsprovide flexible beam definition of symmetric and asymmetric fields. 10 Millennium ™ Multi-Leaf Collimator Dynamic full field high resolution 120 leaf MLC with dual redundant safety readout for most accurate conformal beam shapingand IMRT treatments. 11 Electronic Portal Imager High-resolution PortalVision ™ aS1000 Megavoltage imager mounted on a robotic arm for efficient patient setup verification and IMRT plan QA. 12 On-Board Imager ® kV X-ray source (12a) and high-speed, high-resolution X-ray detector (12b) mounted on two robotic arms orthogonal to the treatment beam for Image Guided Radio Therapy (IGRT).The unique system provides kV imaging at treatment and includes radiographic,fluoroscopic and Cone Beam CT image acquisition and patient repositioningapplications. 6 Focal Spot Size

5

7

3

8

9

2

1

10

12a

12b

11

Utrecht 2016

Made with