ESTRO 2020 Abstract Book

S771 ESTRO 2020

warranted to plot % volume outside PTV vs. dose, indentifying as showed in fig 1, if glands were preserved or not. The plans obtained using AP end eq. 1 were able to minimize the median dose of entire glands reducing risks of toxicity in accordance with guide lines (Merlotti et al. Radiation Oncology 2014); the median dose of entire glands was reduced using AP of 12%±2% and planning time was of 21±8 min vs. 68±19 min planning manually.

comparing ALDO-ILA. The mean of the maximum dose to chiasm was 4.7Gy and 4.4Gy for ALDO and ILA, respectively. The mean of the maximum dose to brainstem was 9.8Gy and 9.4Gy for ALDO and ILA, respectively. For all cases, the V 18Gy <30cc, as prognostic factor for radio- necrosis, was respected (range 5.4-15cc for ALDO and 6.2- 20cc for ILA). MU and OTT were lower for ILA. Mean MU and OTT for ALDO were 4454 and 3 minutes, respectively; while for ILA mean of MU was 2322 and mean of OTT was 1.6 minutes. Conclusion ALDO and ILA give good results of target coverage, OARs sparing and low doses at healthy brain. ALDO uses lower prescription isodoses to obtain similar results to ILA, leading to a D2%>150%Dp, which could correlate with a higher risk of radionecrosis. In SRS planning expert hands, the clinician and physicist might choose between ALDO or ILA to customize treatments based on histology, BMs size and number, proximity to OARs, performing treatment plan optimization tailored on the pt. PO-1447 An Algorithm for 4Pi Radiotherapy Optimization applied to Accelerated Partial Breast Irradiation PO-1448 Fully-automated VMAT treatment planning: head to head between genetic and iterative algorithms C. Fiandra 1 , S. Zara 2 , A. Alparone 2 , P. Franco 1 , S. Bartoncini 3 , L. Rossi 4 , B. Heijman 4 , U. Ricardi 1 1 University of Turin School of Medicine, Radiation Oncology, Turin, Italy ; 2 Tecnologie Avanzate, Research and Development, Turin, Italy ; 3 AOU Città della Salute e della Scienza, Radiation Oncology, Turin, Italy ; 4 Erasmus MC Cancer Institute, Radiation Oncology, Rotterdam, The Netherlands Purpose or Objective To Develop a new Iterative Optimization Algorithm (IOA) within a fully automated treatment planning software and compare results with those of a well-established genetic optimizer in the setting of prostate and head and neck VMAT treatments. Material and Methods A beta version of a new iterative optimization algorithm was implemented on the RayStation treatment planning system (Version 8B) using Python code within the platform named Genetic Planning Solution (GPS version 2.1). The IOA algorithm starts from an initial value of EUD for each organ at risk to generate a sequence of improving approximate solutions, in which the n-th approximation is derived from the previous ones. We compared 20 prostate and 20 head and neck (HN) VMAT GPS plans with newly developed IOA plans. Prostate patients were irradiated with a SIB technique delivering 70.2-61.1 Gy in 26 fractions while a 3 levels approach ( 70-63-54 Gy) was employed for HN treatments. Both algorithms were applied with no human interference. Plan evaluations accounted for dosimetric parameters with DVH based metrics suggested by QUANTEC and adopted in the clinic. In addition, an evaluation metric for plan quality was integrated in the software; it was derived from the same clinical goals giving a unique Percentage Score Value (PSV%), taking into account for both PTV coverage and OARs sparing. Using an interactive Python visual analog scale, a Clinical Blind Score (CBS) study was performed, i.e. the clinician had to blindly select which plan was deemed most suitable and the strength of the difference was expressed in percentage. Abstract withdrawn

Conclusion AP based on linear model for parotid glands resulted a feasible strategy in SIB HNC. Linear model offered the possibility to foresee the expected toxicity in glands before to plan. AP saved planning time offering more time for planner in favour of minor tweaking steps at the end of plans. AP warranted the standardization of high quality plans and treatment outcome in SIB HNC. PO-1446 Multiple brain metastases (BMs) radiosurgery (SRS) with single isocenter: ALDO or ILA? F. Gregucci 1 , I. Bonaparte 1 , A. Surgo 1 , R. Carbonara 1 , A. Fiorentino 1 1 Miulli General Regional Hospital, Radiation Oncology, Acquaviva delle Fonti-Bari, Italy Purpose or Objective SRS is a well-recognized treatment option for pts with limited intracranial disease; recent data show that this approach can be preferred also for pts with multiple BMs. Modern RT techniques applied to Linac-based SRS, have increased the precision of treatment, improving target dose distribution and reducing normal tissue doses. A dedicated mono-isocenter technique with multiple non- coplanar arcs could be performed, allowing to minimize overall treatment time (OTT) and geometrical/setup uncertainties. We compared 2 different optimization approaches in terms of isodose prescription, target coverage and organs at risk (OARs) dose sparing. Material and Methods 69 BMs (mean7, range4–21) were treated by Single iscocenter SRS in 10 pts. Prescribed dose (Dp) was 27Gy in 3 fr. PTV was defined by 1 mm isotropic margin from each lesion. None of PTVs was overlooking to chiasm or brainstem. Mono-isocenter VMAT plans with 5 non- coplanar arcs (couch at 0°, ±45°, ±90°) were generated for all pts, 2 different modalities of optimization –one based on mono-isocenter SRS dedicated optimization tool and the other on human experience – were compared: Automatic Lower Dose Objective (ALDO) vs Intratumor Lower dose Approach (ILA). A dose normalization of 100%Dp at 98%PTV was adopted, while D2%(PTV)<150%Dp was accepted. OARs were: chiasm, brainstem and heathy brain minus PTVs. Plan-optimizations were compared by the isodose prescription, D100% and D2% for PTVs, maximum dose for chiasm and brainstem, V 18Gy for the healthy brain, number of monitor units (MU) and OTT. Results Sum of PTVs, calculated for each pts as an index of intracranial disease, had mean dimension of 5.6cc (range 3.71–10.1cc). The isodose prescription for ALDO were between 60-65%, for ILA between 75-80%. For both D100% between 25,05-27,3Gy, D2% was higher for ALDO than ILA: 38-39Gy for ALDO and33-34Gy for ILA. All plans had to respect the constraints on maximum dose to the chiasm (D0.5cc <15Gy) and to the brainstem (D0.5cc <18Gy) and no difference was highlighted by

Made with FlippingBook - professional solution for displaying marketing and sales documents online