ESTRO 2021 Abstract Book
S268
ESTRO 2021
Results For the intra-patient models, the largest M res
were observed in the region around the oropharynx. The
maximum M res obtained between the DVF observed in the following weeks of treatment and the predicted DVF between the deformation observed in the last week of treatment and the predicted deformation for one of the patients where the maximum value observed in that region was 6.3 mm. For the inter-patient model, Figure 2B shows the mean M res across the 119 DVFs not used for model creation for the training patients and across all 162 DVFs from all validation patients. As it was observed for the intra- patient models, for both sets of patients, the mean M res is the largest in the region around the oropharynx, with a maximum value of 3.4 mm for the training patients and 3.7 mm for the validation patients. Within this region, the maximum M res values range from 2.3-14.0 mm in DVFs from the training patients and 2.5-13.1 mm for the validation patients. ranged from 3.9-12.5 mm. Figure 2A shows the M res
Made with FlippingBook Learn more on our blog