ESTRO 2022 - Abstract Book
S1383
Abstract book
ESTRO 2022
PO-1599 Comparison of Deep Learning synthetic CT methods for CBCT-guided adaptive prostate radiotherapy
Y. de Hond 1 , C. Kerckhaert 1 , P. van Haaren 1 , R. Tijssen 1
1 Catharina Hospital, Radiotherapy, Eindhoven, The Netherlands
Purpose or Objective To improve CBCT quality, several deep-learning (DL) networks have been proposed to generate synthetic CTs (sCTs). These networks learn a transform between CBCT and planning CT (pCT) scans. While these networks are successful in areas like head & neck and thoracic cancer, the variable bladder and rectal filling poses considerable challenges for pelvic tumor sites. It is therefore unknown which type of DL architecture is most suitable for prostate cancer. In this study, paired and unpaired DL networks were assessed with focus on the structural agreement of the synthetic CT with the daily CBCT. Materials and Methods A previously published Unet [1] and a CycleGAN [2] were trained assessed on pCT and first fraction CBCT images of 57 prostate cancer patients, acquired on a Philips big bore CT and Elekta XVI system respectively. Average interval between CBCT and pCT scan was 20 days (min 2, max 56). Preprocessing : signal intensities were normalized. PCT was registered to CBCT rigidly (rpCT) and deformed (dpCT) with Elastix registration toolbox v5. Training : Unet was trained with CBCT and rpCT as paired input and dpCT as ground truth (GT). Images with no acceptable deformable image registration (DIR) between pCT and CBCT were excluded in training, which resulted in 2236 training, 1073 validation and 482 test images. CycleGAN was trained with unpaired input CBCT and GT dpCT, with a number training/validation/test images of 3928/1073/482, respectively. Both models were trained for 200 epochs and lowest validation error epoch was used. Evaluation : sCT images were evaluated on the mean absolute error (MAE), structural similarity index measure (SSIM) between sCT and dpCT (GT). In addition, the rectal volume was determined to assess structural agreement with the CBCT. Results Fig. 1 shows a typical example from our test set. DIR was, even after fine-tuning, not always capable to reflect the anatomy changes due to variable rectal filling in the CBCT. This anatomical mismatch was also observed in the sCT generated by the Unet. Conversely, the CycleGAN was able to better preserve the anatomy of the CBCT, which is also reflected by the absolute differences in rectal volume between the CBCT and sCT (Fig 2). The MEA and SSIM, however, favored the Unet (MAE: 21.8±7.0 HU and 37.5±9.2 HU, and SSIM: 0.97±0.01 and 0.94±0.02 for Unet and CycleGAN, respectively). These differences were mainly driven by the fact that the Unet (incorrectly) aligned better with the dpCT, thus mimicking the registration errors between the dpCT and CBCT.
Made with FlippingBook Digital Publishing Software