Conclusion Described procedure yields an estimated range calculation uncertainty of 1.6% for the chosen tissue configuration in a real CT. In VCT the estimated uncertainty increases up to 2.9%, a value that could be used for on-line adaptive proton therapy workflows. These uncertainties could be reduced excluding from analysis areas of high uncertainty due to air-tissue interfaces. 2.9% could be low enough to assess actual dose delivery with less uncertainty than QA CTs, as the image is acquired in treatment position. The validation of this results with different setups and/or tissues configuration could yield to an actual department range uncertainty estimation and help to reduce range margin in robust treatment planning.
PO-1988 Feasibility of bi-criteria optimization applied to proton arc therapy treatment planning
S. Wuyckens 1 , L. Zhao 2 , M. Saint-Guillain 3 , G. Janssens 4 , A. Barragan Montero 1 , E. Sterpin 1,5 , K. Souris 6,1 , X. Ding 7 , J. Lee 1
1 UCLouvain, MIRO, Brussels, Belgium; 2 Beaumont Health, Department of Radiation Oncology, Royal Oak, USA; 3 UCLouvain, ICTEAM, Louvain-La-Neuve, Belgium; 4 Ion Beam Applications SA, R&D, Louvain-La-Neuve, Belgium; 5 KULeuven, Department of Oncology, Leuven, Belgium; 6 Ion Beam Applications SA, IBA Dosimetry , Louvain-La-Neuve, Belgium; 7 Beaumont Health, Department of Radiation Oncology , Royal Oak, USA Purpose or Objective Proton arc therapy (PAT) is a new delivery technique that exploits the continuous rotation of the gantry to distribute the therapeutic dose over many angular windows instead of using a few static fields, as in conventional (intensity-modulated) proton therapy. Although coming along with many potential clinical and dosimetric benefits, PAT has also raised a new optimization challenge. In addition to the dosimetric goals, the beam delivery time (BDT) needs to be considered in the objective function. Considering this bi-objective formulation, finding a good compromise with appropriate weighting factors turns out to be cumbersome. The goal of this study is to demonstrate the feasibility of applying a bi-criteria optimization (BCO) algorithm to a restated PAT problem, to investigate the trade-offs between the plan quality and the delivery time. Materials and Methods The BCO algorithm computes a database of Pareto-optimal plans, i.e., treatment plans for which no other better plan exists in every measurable dimension. We have implemented the BCO algorithm in an in-house treatment plan system, OpenTPS, and computed Pareto-optimal arc plans for three disease sites: a brain, a lung, and a liver. The method iteratively picks weight vectors to approximate the Pareto front with few points. Mixed-Integer Programming was selected to restate PAT as a bi-criteria problem and to find Pareto optimal points with a suited solver. Results For each patient, the Pareto frontier is approximated by a set of Pareto-optimal points (Figure 1a, brain case). Next, the trade-offs between plan quality and beam irradiation time (static BDT) are investigated by inspecting three plans from the Pareto front. The latter are carefully picked to demonstrate significant differences in dose distribution (Figure 1c, brain case) and delivery time depending on their location on the frontier as reported in the table (Table 1) and in the dose- volume histograms (Figure 1b). The first point D_t brings the plan with the highest quality but the largest irradiation time while the point d_T does the complete opposite. Finally the intermediate point d_t shows a better compromise between both objectives, losing 1Gy in target coverage but reducing by almost 50% the irradiation time for the brain case. However,
Made with FlippingBook - professional solution for displaying marketing and sales documents online