ESTRO 2023 - Abstract Book

S1940

Digital Posters

ESTRO 2023

of IS GYN BT uses a transperineal catheter-guiding template in combination with an intrauterine (IU) tandem. Typically, catheter locations are decided based on pre-BT imaging, and radiation treatment plans are then determined based on imaging taken after catheter insertion. This can lead to suboptimal tumor coverage, and often unused catheters, which contribute to increased implantation time and tissue injury. Instead, changes to patient anatomy due to the IU tandem suggest that images taken after insertion of the Tandem and APPlicator (post-TAPP) may be better suited than pre-BT images for catheter planning. In previous studies on prostate BT, the use of catheter optimization algorithms could quickly produce equivalent or superior treatment plans using fewer IS catheters compared to clinical cases. To verify these findings for GYN BT, we implemented a Centroidal Voronoi Tessellation (CVT) algorithm for catheter optimization in prior cervix cancer cases. CVT uniformly distributes a given number of catheters throughout a 2D projection of the target volume. We therefore hypothesize that using CVT for catheter planning on post-TAPP MRI will improve or maintain treatment plan quality with fewer catheters. Materials and Methods Cases of locally advanced cervical cancer treated from 2017 to 2019 using IS BT with a Syed Neblett template were selected (N=6). Target, organ-at-risk (OAR), and clinical catheter delineations were retrieved from post-insertion imaging. CVT was used to simulate post-TAPP optimized catheters for each case. Treatment plans were then generated by a single expert for both the CVT and clinical catheter arrangements. Plan quality was evaluated via compliance with the clinically used EMBRACE-II dose-volume constraints. Measures of dose inhomogeneity (%V150 and %V200) were also recorded. Results In all cases but 1, the CVT arrangements produced improved or EMBRACE-II compliant treatment plans with as many or fewer inserted catheters compared to the clinical cases (Table 1). A small increase in %V150 was observed between sample groups (p < 0.05). Additionally, the clinical cases resulted in 20 total unused catheters (ex. Fig. 1), while those with CVT had only 1 total. 2 plans using clinical catheters failed to meet target dose minimums, and thus would have required a new implant in clinical practice; however, the plans using CVT catheters for the same patients met all, and all but 1, clinical objectives respectively.

Conclusion This preliminary retrospective work supports the hypothesis that CVT with post-TAPP imaging can achieve clinically acceptable dose distributions while limiting insertion of extraneous catheters. Future work aims to increase the cohort size and further quantify the effect of lowering the number of CVT catheters.

PO-2157 Automated MCO to assess dosimetric price-to-pay for control on loading pattern in cervical cancer BT

L. Rossi 1 , N. Panico 1,2 , S. Breedveld 1 , N. Lanconelli 3 , R. Nout 1 , B. Heijmen 1

Made with FlippingBook - professional solution for displaying marketing and sales documents online