ESTRO 2023 - Abstract Book

S1326

Digital Posters

ESTRO 2023

higher brain V12Gy. Other organs at risk were never significantly interested by clinically relevant doses. The SL mCP registered a lower median MU number while ML mCP results were obtained with a higher median number of MU. In both cases, this difference was not statistically significant and plans registered a comparable local gamma analysis (2%/2mm). Conclusion The novel mCycle autoplanning produced high-quality clinically acceptable radiosurgery SL and ML plans with coplanar arcs, significantly reducing the overall planning time from about one working day for one MP to about 3 hours for one mCP. Together with comparable OAR sparing, the target coverage was significantly increased and preserving the plan deliverability. The validation showed the mCycle capability to generate high-quality deliverable plans according to institutional-specific planning protocols.

PO-1631 Commercial deep learning-based automated treatment planning validation for oropharyngeal cancer

F. Dankers 1 , P. Balasupramaniam 2 , M. Brussee 1 , A. Onderwater 1 , M. de Jong 1 , E. Astreinidou 1

1 Leiden University Medical Center, Radiotherapy, Leiden, The Netherlands; 2 VU University, Faculty of Science, Amsterdam, The Netherlands Purpose or Objective Radiotherapy treatment planning for head and neck cancer (HNC) is a labor-intensive process which can take up to a day per patient. Additionally, plan quality is highly dependent on the experience of the treatment planner. RayStation 10B offers deep learning-based autoplanning (DLAP) functionality using a 3D convolutional neural network which is claimed to generate clinically acceptable and deliverable treatment plans within 15 minutes. In this study, the performance of RayStation DLAP for oropharyngeal cancer is investigated by carrying out a dosimetric comparison between DLAP plans and corresponding clinical treatment plans that were manually generated. Materials and Methods The RayStation DLAP model was trained by RaySearch on 100 HNC plans that conformed to the DAHANCA guidelines. The model was iteratively tuned to our department’s requirements by RaySearch using a training set of 5 patients, and validated on a set of 14 patients (unseen by RaySearch). Final DLAP plans, after five tuning rounds, were dosimetrically compared to the corresponding 14 clinical plans. All patients had oropharyngeal cancer and received 54.25 Gy to the elective lymph nodes (dose level 1) and 70 Gy to the primary tumor (dose level 2). Comparison of DVH parameters was performed using boxplots for clinical and planning target volumes as well as relevant organs at risk. Statistical significance was tested using a two-tailed Wilcoxon signed-rank test at the 0.05 level. Results DLAP plan generation took less than 15 minutes per plan. Target coverage for both dose levels met the clinical constraints (V95% ≥ 98%). Target coverage of the elective nodes increased significantly for the DLAP plans when compared to the clinical plans, from CTV V98% = 99.2 (98.7-99.3) % in the clinical plans to 99.6 (99.2-99.8) % in the DLAP plans, and from PTV V95% = 98.0 (98.0-98.1) % to 98.3 (98.2-98.4) % (see Figure 2). Target coverage of the tumor showed less variation in the DLAP plans (not significant). The mean dose for both target volumes increased significantly in the DLAP plans (median increase of 0.5% for both target volumes). OAR dose was either similar or decreased for the DLAP plans. Statistical significant decrease was observed for the glottic area, larynx supraglottis, and inferior and superior pharyngeal constrictor

Made with FlippingBook flipbook maker