ESTRO 2023 - Abstract Book
S1351
Digital Posters
ESTRO 2023
Physics, Naples, Italy; 6 Fondazione Policlinico Universitario A. Gemelli IRCCS, uosd medical physics and radioprotection, Rome, Italy Purpose or Objective The aim of this study was to test the transferability of Knowledge-based (KB) plan prediction models trained in several Institutes with free-breathing (FB) left whole-breast (LWB) tangential-field (TF) in patients submitted to deep inspiration breath-hold (DIBH) LWB TF irradiation. Materials and Methods In the context of a national multi-institutional project, eight institutes set LWB-TF KB models by using RapidPlan (Varian Inc.), following previously agreed methodology for model’s building and validation. One of the eight institutes provided an additional model trained with a LWB-TF DIBH population (INST1DIBH), considered in the study as a “benchmark” of the prediction on DIBH candidates. Models were tested on 20 new LWB-TF DIBH randomly chosen patients from five out of the eight institutes aiming to perform a cross validation test. Transferability of the nine models (i.e.: eight free-breating, one DIBH) on DIBH geometry/anatomy was assessed considering the overlap of the geometric Principal Component (PC1) when applied to the 20 test patients (normalized to the 40Gy/15 fraction scheme). The degree of transferability was quantified by the number of cases in which the ipsilateral lung and heart PC1 was within the 90th percentile of the training set. PC1 was previously shown to be a robust parameter to quantify if a model can be reasonably applied to a patient outside the training cohort in terms of DVH prediction. In addition, the heart and lung mean predicted dose (Dmean), lung V20Gy, heart V5Gy and V25Gy were also included in the analysis aiming to quantify inter-Institute variability in plan prediction. Results Figure 1 shows the fraction of DIBH patients with PC1 within the 90th percentile of the training set for all models. Ipsilateral lung provided good results in terms of transferability: PC1 values were inside in 8 out of 9 models for at least 90% of patients. Concerning heart, PC1 values out of the 90th percentile, ranged from 5% to 30% with only 3 out of 9 models with PC1 inside for at least 90% of patients. INST1DIBH’s model heart PC1 was within 90th for all patients. Concerning the mean and V20Gy predicted ipsilateral lung dose, SDmean=0.8 Gy and SDV20Gy=2.8% were found. Regarding the heart, SDmean= 0.4 Gy, SDV5Gy=1.4% and SDV25Gy=0.8% were found (Figure2). Inter-institute SD of DVH prediction in the dose range from 20% to 80% was 0.4% and 2% for heart and ipsilateral lung respectively
Made with FlippingBook flipbook maker