Conclusion The proposed workflow allows for patient-specific assessment of correspondence models stability over the course of treatment and to identify patients that would benefit from adaptive re-planning. Corresponding DSC thresholds (e.g. >0.7) need to be confirmed using a larger cohort.
PO-1918 Comparison of total replanning and fast template-based planning for online adaptive radiotherapy
B. Tengler 1 , L.A. Künzel 2,3 , D. Zips 4 , C. Gani 4 , S. Böke 4 , D. Wegener 4 , D. Thorwarth 1
1 Section for Biomedical Physics, Department of Radiation Oncology. University Hospital and Medical Faculty. Eberhard Karls University Tübingen, Tübingen, Germany; 2 National Center for Tumor Diseases (NCT), Dresden, Germany, German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; Helmholtz-Zentrum Dresden – Rossendorf (HZDR), Dresden, Germany; 3 Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; 4 Department of Radiation Oncology, University Hospital and Medical Faculty. Eberhard Karls University Tübingen, Tübingen, Germany Purpose or Objective Daily treatment plan adaptation provides the opportunity for adjustments of the dose distribution based on the daily anatomy. To realize an online adaptive workflow, the planning must be performed in a few minutes. This can be achieved by simplification and automation of plan optimization, segmentation and dose calculation. For treatment planning it is possible to reduce the time by using a predefined template based on a reference plan that is adjusted to the daily anatomy. The aim of this study was to investigate the dosimetric variation after anatomic changes and benefits complete replanning brings to plan quality. Materials and Methods In this retrospective planning study, ten prostate patients treated at a 1.5T MR-Linac (20x3 Gy) were included. The organs at risk in the CT- and MRI images were segmented using an auto segmentation algorithm. All target volumes were contoured by radiation oncologists. An automated treatment planning algorithm based on a particle swarm optimization (PSO) was used to create a reference plan for each patient. With the reference plan as a template, adapted radiotherapy plans were optimized for every fraction based on the daily MR-derived anatomy without changing any optimization constraints. For comparison, a second treatment plan was created for each MR-adaptive fraction by carrying out a full PSO replanning allowing for constraint alteration. The resulting 144 plans, for each method, were compared based on overall compliance with 14 dosimetric criteria shown in Figure 1(A). Furthermore, relative volume differences between reference geometry/structure and adaptive treatment fraction were assessed for PTV60, PTV57.6, rectum and bladder. Correlations of volume changes and the dosimetric criteria was investigated using spearman correlation. Results The template approach was more likely to fail criteria than the PSO (see Figure 1(B)). In 60% of PSO plans at most one criterion was not reached compared to 37.5% in the template plans. A strong correlation (rs=0.66) between PTV60 coverage and relative bladder volume change was observed in the template plans. Additionally, a moderate correlation (rs=0.44) between rectum circumference and rectum volume was recognized in Figure 2(A). Figure 2(B) indicates that reduced bladder volume leads to lower dose coverage. Plans with a bladder volume reduction over 50% compared to the reference plan showed low dose coverage under 56 Gy for PTV60.
Made with FlippingBook flipbook maker