The higher median DI during beam-on time suggests a possible psychological effect of the noise or motion of the treatment machine on patients. Further inspection of SGRT data will help evaluate the DI tolerances in use at our clinic. PD-0748 Evaluation of intrafraction duodenum positional stability for pancreatic SABR on the MR-Linac M. Daly 1 , A. Choudhury 1,2 , R. Chuter 1,3 , B. Erickson 4 , W. Hall 4 , A. McWilliam 1,3 , E. Vasquez Osorio 1 , G. Radhakrishna 2 , H. Verkooijen 5 , C. Eccles 1,6 1 The University of Manchester, Division of Cancer Sciences, Manchester, United Kingdom; 2 The Christie NHS Foundation Trust, Clinical Oncology, Manchester, United Kingdom; 3 The Christie NHS Foundation Trust, Medical Physics & Engineering, Manchester, United Kingdom; 4 Medical College of Wisconsin, Department of Radiation Oncology, Milwaukee, USA; 5 University Medical Center Utrecht, Imaging Division, Utrecht, The Netherlands; 6 The Christie NHS Foundation Trust, Radiotherapy, Manchester, United Kingdom Purpose or Objective The duodenum is a dose-limiting organ at risk (OAR) in pancreatic stereotactic ablative radiotherapy (SABR). MR-Linac SABR delivery can be associated with longer treatment times than conventional Linacs, increasing the possible impact of intrafraction motion on planned dosimetry. The purpose of this study is to evaluate the intrafraction stability of the duodenum, the impact of treatment duration on stability, and whether a 5 mm planning at risk volume (PRV) is adequate. Materials and Methods Pancreatic SABR patients with intact duodenum treated with abdominal compression on the MR-Linac under an international prospective registry study (NCT04075305) were included. 3D T2-weighted or motion compensated MRIs were acquired before treatment (MRIpre) and either before treatment delivery (verification) or post-treatment (MRIpost). Intrapatient sequences were consistent. The duodenum was contoured on all images by one observer and divided into 4 anatomical segments (Fig. 1a). We assessed intrafraction duodenum changes by 1) difference in volume, 2) displacement of centre of mass (COM) of duodenum and individual segments and 3) mean distance to agreement (mDTA) of whole duodenum on MRIpre (Dpre) and on MRIpost (Dpost). Time between images was calculated for each patient on all fractions. A 5 mm PRV was generated using Dpre, and then rigidly copied to MRIpost. The volume of underlap of Dpost with the Dpre PRV was calculated. The underlap between this volume and the planning target volume (PTV) expanded by 2cm was evaluated to determine whether the duodenum was displacing towards the high-dose region. The difference in pooled mean absolute 3D vector of segment COM of Dpre and Dpost was tested for significance with single factor ANOVA, and association with time between scans assessed using Pearson’s correlation. Results 15 patients received 33-40 Gy in 5 fractions (#). MRIpost treatment/verification data were not available for 3 patients for 1 # each. These were excluded from analysis, leaving 72 evaluable fractions. There was evidence of some intra-fraction duodenal drift; the number of fractions where Dpost was outside of PRV, and number of # where this underlap was within 2cm of PTV are shown in Table 1. No strong association was found between time between scans and duodenum COM displacement in X, Y or Z planes (r=-0.17, 0.02, -0.04 respectively), nor for absolute 3D vector of displacement (r=0.15) (Fig. 1B). The difference in pooled mean absolute 3D displacement vector between segments was not significant (p=0.6).

Conclusion Whole and sub-organ duodenum position and volume is stable for the majority of patients across a treatment fraction of approximately 40mins, with a 5mm PRV being adequate within 2 cm of PTV. Longer treatment durations may increase the

Made with FlippingBook flipbook maker