Figure 2: Percentage difference of dose constraints achieved between the PSMA-PET/CT reference plan versus fraction 1
Conclusion:
We have successfully demonstrated the first clinical implementation of simulation-free Unity MR-Linac treatment for prostate SBRT, highlighting diagnostic PSMA-PET/CT scans can be used in-lieu of simulation-CT. The workflow on the MR-Linac was able to adapt to anatomical variations between the PSMA-PET/CT reference plan and fraction 1, including the insertion of rectal spacing after the PSMA-PET/CT. This workflow can benefit patients by eliminating simulation scans, reducing their overall amount of time spent at the clinic, and potentially expediting time to treatment. This workflow is now the standard of care for patients receiving prostate SBRT on the MR-Linac in our centre.
Keywords: Simulation free, MRI Linac, Stereotactic Prostate
References:
1. Persson E, Svanberg N, Scherman J, Jamtheim Gustafsson C, Fridhammar A, Hjalte F, Bäck S, Nilsson P, Gunnlaugsson A, Olsson LE. MRI-only radiotherapy from an economic perspective: Can new techniques in prostate cancer treatment be cost saving? Clin Transl Radiat Oncol. 2022 Nov 22;38:183-187. doi: 10.1016/j.ctro.2022.11.012. PMID: 36479236; PMCID: PMC9720486. 2. Rammohan N, Randall JW, Yadav P. History of Technological Advancements towards MR-Linac: The Future of Image-Guided Radiotherapy. J Clin Med. 2022 Aug 12;11(16):4730. doi: 10.3390/jcm11164730. PMID: 36012969; PMCID: PMC9409689. 3. Carr ME, Jelen U, Picton M, Batumalai V, Crawford D, Peng V, Twentyman T, de Leon J, Jameson MG. Towards simulation-free MR-linac treatment: utilizing male pelvis PSMA-PET/CT and population-based electron density assignments. Phys Med Biol. 2023 Sep 22;68(19). doi: 10.1088/1361-6560/acf5c6. PMID: 37652043.
Made with FlippingBook - Online Brochure Maker