ESTRO 2024 - Abstract Book

S3436

Physics - Dose calculation algorithms

ESTRO 2024

3. Cuculich, C.R.a.P., Noninvasive Cardiac Radioablation for VT: Lessons Learned and Future Directions. ACC, 2019. 4. Robinson, C.G., et al., Phase I/II Trial of Electrophysiology-Guided Noninvasive Cardiac Radioablation for Ventricular Tachycardia. (1524-4539 (Electronic)). 5. Chang, B.K. and R.D. Timmerman, Stereotactic body radiation therapy: a comprehensive review. (1537-453X (Electronic)). 6. Knutson, N.C., et al., Radiation Therapy Workflow and Dosimetric Analysis from a Phase 1/2 Trial of Noninvasive Cardiac Radioablation for Ventricular Tachycardia. (1879-355X (Electronic)). 7. Wang, L., et al., Stereotactic Arrhythmia Radioablation (STAR) of Ventricular Tachycardia: A Treatment Planning Study. (2168-8184 (Print)). 8. Gianni, C., et al., Stereotactic arrhythmia radioablation for refractory scar-related ventricular tachycardia. (1556-3871 (Electronic)). 9. Tillikainen, L., et al., A 3D pencil-beam-based superposition algorithm for photon dose calculation in heterogeneous media. (0031-9155 (Print)). 10. Fogliata, A., et al., Dosimetric validation of the Acuros XB Advanced Dose Calculation algorithm: fundamental characterization in water. (1361-6560 (Electronic)). 11. Van Esch, A., et al., Testing of the analytical anisotropic algorithm for photon dose calculation. (0094-2405 (Print)). 12. Aarup, L.R., et al., The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: implications for tumour coverage. (1879-0887 (Electronic)). 13. Fogliata, A., et al., Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media. (1748-717X (Electronic)). 14. Bush, K., et al., Dosimetric validation of Acuros XB with Monte Carlo methods for photon dose calculations. (0094-2405 (Print)). 15. Padmanaban, S., et al., Comparison of Acuros (AXB) and Anisotropic Analytical Algorithm (AAA) for dose calculation in treatment of oesophageal cancer: effects on modelling tumour control probability. (1748-717X (Electronic)). 16. Fogliata, A., et al., On the dosimetric impact of inhomogeneity management in the Acuros XB algorithm for breast treatment. (1748-717X (Electronic)). 17. Han, T., et al., Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancer. (2473-4209 (Electronic)). 18. Kroon Ps Fau - Hol, S., M. Hol S Fau - Essers, and M. Essers, Dosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated arc therapy plans. (1748-717X (Electronic)).

1980

Mini-Oral

Validation in a clinical setting of a deep learning-based out-of-field dose estimation tool.

Nathan Benzazon 1,2 , Meissane M’hamdi 1,2 , Pauline Maury 1,2 , François de Kermenguy 1,2 , Mohammed El-Aichi 1,2 , Cathyanne Schott 1,2 , Julie Colnot 1,2,3 , Eric Deutsch 1,2 , Ibrahima Diallo 1,2 , Charlotte Robert 1,2

Made with FlippingBook - Online Brochure Maker