ESTRO 2024 - Abstract Book
S3454
Physics - Dose calculation algorithms
ESTRO 2024
Figure 1: Examples of dose distributions corresponding to a) AAA-optimized plan, b) AXB-Dm,m-optimized plan, and c) AXB-Dm,m-optimized and AAA-recalculated plan. Dose-volume histograms of the skull (blue) and the CTV (orange) are shown below.
Conclusion:
Switching from convolution/superposition to advanced algorithms in the treatment of meningiomas infiltrating bone, without further considerations in the planning process and approach, results in significant dose differences within the bone tissue infiltrating the CTV and the CTV itself. These differences have the potential to enhance the TCP, at the expense of increased NTCP in bone and a reduction of dose homogeneity within the CTV. The dosimetric and potential clinical impacts should be rigorously assessed when implementing advanced algorithms in clinical practice.
Keywords: advanced algorithms, meningiomas, DVH
3081
Digital Poster
Algorithm for PTV minimisation in linear accelerator-based liver Stereotactic Ablative Radiotherapy
Made with FlippingBook - Online Brochure Maker