ESTRO 2024 - Abstract Book
S3670
Physics - Dose prediction, optimisation and applications of photon and electron planning
ESTRO 2024
Results:
Table 1 displays the difference for some of the in total 33 parameters examined (ΔParameter=Parameter(VMAT)- Parameter(DCA)). It also indicates the significance of the difference. Most of the depicted differences (e.g. conformity index (CI), gradient index (GI) and the bridging dose (BD)) were statistically significant, while the difference for the low dose region represented by the volume receiving 5 Gy (V5) was not statistically significant.
Metric
medianVMAT medianDCA
Δmedianabs Δmedianrel
p value
Significant
CI
1.10
1.23
-0.13
-10.38
5.20e-54
True
GI
4.26
3.81
0.45
11.87
1.18e-32
True
Coverage
0.99
0.99
0.00
0.02
7.89e-18
True
BD [rel]
0.40
0.40
0.00
0.68
2.03e-12
True
Dmean [Gy]
27.50
27.94
-0.43
-1.55
1.07e-09
True
Dmax [Gy]
31.29
30.45
0.85
2.78
1.71e-09
True
V5 [ccm]
10.42
10.18
0.25
2.44
0.12
False
V10 [ccm]
3.25
3.40
-0.16
-4.55
2.60e-08
True
V12 [ccm]
2.16
2.40
-024
-10.09
7.96e-08
True
V100% [ccm]
0.06
0.16
-0.10
-61.00
3.59e-53
True
Table 1: Some of the evaluated Parameters
All 33 examined parameters were correlated with each other. The resulting correlation matrix is depicted in Figure 1.
Made with FlippingBook - Online Brochure Maker