ESTRO 2024 - Abstract Book
S4221
Physics - Intra-fraction motion management and real-time adaptive radiotherapy
ESTRO 2024
Figure 2. Boxplots of V95% (top) and D5%-D95% (bottom) for the CTV show the impact of 10 different starting phases for no rescanning. The diamonds mark the values of the static plans, while different coloured circles show the dosimetric indices for different starting phases.
Conclusion:
This exploration pioneers the investigation of the simultaneous impact of magnetic fields and respiratory motion in onboard MR-guided PBS proton therapy. Comparable dosimetric effects were observed across varying magnetic field strengths, indicating that the motion effects for MR-guided proton therapy may not present more significant challenges than those encountered in conventional PBS proton therapy.
Keywords: MR-guidance, 4D dose calculation, PBS proton
References: