ESTRO 2024 - Abstract Book

S5782

RTT - Education, training, advanced practice and role developments

ESTRO 2024

Keywords: prehabilitation, lung, radiographer-led

References:

1. Islam KMM, Jiang X, Anggondowati T, Lin G, Ganti AK. Comorbidity and Survival in Lung Cancer Patients. Cancer Epidemiology Biomarkers & Prevention. 2015 Jun 11;24(7):1079–85.

2. Tammemagi CM, Neslund-Dudas C, Simoff M, Kvale P. Impact of comorbidity on lung cancer survival. International Journal of Cancer. 2003 Jan 6;103(6):792–802.

3. Granger CL, McDonald CF, Berney S, Chao C, Denehy L. Exercise intervention to improve exercise capacity and health related quality of life for patients with Non-small cell lung cancer: A systematic review. Lung Cancer. 2011 May;72(2):139–53.

4. Anthonisen NR, Skeans MA, Wise RA, Manfreda J, Kanner RE, Connett JE. The Effects of a Smoking Cessation Intervention on 14.5-Year Mortality. Annals of Internal Medicine. 2005 Feb 15;142(4):233.

1403

Poster Discussion

To what extent does proton imaging training enhance confidence in reviewing proton plans

Rachael A Bailey 1 , Thomas Edwards 2 , Jane Miller 2 , Helen Young 2 , Philip Fendall Amaro 1 , Lucy Davies 1 , Jacqui Bridge 1 , Lee Whiteside 1 , Louise McHugh 1 , Robert Appleyard 3 1 The Christie NHS Foundation Trust, Radiotherapy, Manchester, United Kingdom. 2 The Christie NHS Foundation Trust, Proton Beam Therapy, Manchester, United Kingdom. 3 Sheffield Hallam University, Faculty of Health and Wellbeing, Sheffield, United Kingdom

Purpose/Objective:

The increased clinical demand of patients eligible, associated costs, and the impracticalities of sending patients overseas initiated the commissioning of two proton beam therapy (PBT) centres in the UK, by NHS England 1 . An important aspect of the development of protocols and procedures in a new PBT NHS service involves Therapeutic Radiographer image verification training, which is standardised and provided in-house as part of a newly developed and comprehensive induction programme. Alongside a more conformal target volume to adhere to, in comparison to photon radiotherapy, within PBT there is inherent additional complexity, such as a variety of range uncertainties, the potential impact of organ motion and set up variations are amplified. Due to proton sensitivity, serious consideration is therefore required to ensure the accurate deposition of dose, dictating that daily IGRT is paramount 2 . A heavy reliance on image verification within PBT

Made with FlippingBook - Online Brochure Maker