ESTRO 36 Abstract Book
S857 ESTRO 36 _______________________________________________________________________________________________
radiotherapy (CK-based SRT) by the planning and treatment parameters in patients group suffering from orbital’s tumors: ocular melanoma and orbital metastases. Treatment plans for patients with orbital’s tumor undergoing CK-based SRT are often challenging due to the close proximity of optic apparatuses. Material and Methods Feasibility of the eye fixation system was evaluated in the present study using data of 15 patients treated by 1 do 14 with median 5 fractions. The treated PTV volume ranged from 0.73-37.59 cm 3 (median 2.83 cm 3 , mean 7.15 cm 3 , ± SD 11.98). The prescription dose ranged from 20-50 Gy with median value 50 Gy prescribed to the 80% isodose. The eye fixation system was the polymetric device which was attached to the mask system in cranio-caudal orientation and placed in front of the diseased eye (visualization of the system at figure 1 left). The patient was looking at the black point placed at the arm of the eye’s fixation system. The proper position of eye during the imaging and treatment was fixed and the position of the system can be easily adjusted and fixed to the suitable position for any patients. The position of the system was defined by CT and used during treatment delivery. CK- based SRT of orbital’s tumors were evaluated by PTV coverage, conformity index (CI), total number of monitor units (MU), number of beams and the treatment time and the maximum dose to ipsilateral optic nerve were likewise to assess delivery efficiency. Results The optical fixation system was well tolerated by all patients and the stable position of the eye was obtained. The system can be used during planning and treatment without any interference with the photon beam, doses to the eye’s fixation system ranged from 0.03 – 3.71 Gy (median 0.97 Gy, mean 1.15 Gy, ± SD 1.11). Figure 1 showed the treatment plan of one patient treated on the CK-based SRT using the eye’s fixation system. Average treatment parameters of 15 total orbital’s lesions (Table 1). Figure 1. CK-based SRT treatment plan displayed in the axial plane of the patients with a medial orbital tumor in the right eye and multiple beam trajectories.
Table 1. Average treatment parameters of 15 total orbital’s lesions.
EP-1591 Evaluation of noninvasive eye fixation system on Cyberknife radiotherapy of orbital’s tumors A. Skrobala 1,2 , M. Adamczyk 1 , P. Janiga 3 , A. Jodda 1 , J. Litoborska 1 , E. Czajka 3 , J. Dura 3 , P. Milecki 2,3 1 Greater Poland Cancer Centre, Medical Physics Department, Poznan, Poland 2 University of Medical Science, Department of Electroradiology, Poznan, Poland 3 Greater Poland Cancer Centre, Ist Radiotherapy Department-, Poznan, Poland Purpose or Objective Purpose of this study was to evaluate noninvasive eye fixation system on CyberKnife-based stereotactic
Conclusion The results of this study and good clinical outcomes demonstrated the feasibility of the eye fixation devices for CK-based SRT without the need of implementing fiducial markers. Two years follow up reported that the salvage therapy (enucleation) was unneeded in all cases. CK-based SRT appeared to be a relatively safe technique in treating orbital’s lesions within or near optic apparatuses. CK-based SRT using fixation system provides excellent tumor coverage without delivering excessive dose to critical anterior structure and provided that the dose to the optic apparatuses were limited. The long-term safety of this treatment remains to be confirmed.
Made with FlippingBook