Literature data dose constraints rectum and bladder
Study
Bladder constraints
Rectum constraints
Sigmoid constraints
Femoral heads
Jhingran et al. (RTOG 0418)
V45<35%
V45<60%
V30<15%
Gandhi et al. (AIIMS)
V40<40% Dmax <50Gy
V40<40% Dmax <50Gy
Mouttet –Audouard et al (Centre Oscar Lambret)
V40<50% V45<20% Dmax<60Gy
V40<50% V45<20% Dmax<60Gy
V40<50% V45<20% Dmax<60Gy
Mabuchi et al.
V50<35%
V50<35%
V30<20%
Summary
V 40 < 35 – 40%
V40 < 40 - 50%