Planning aim and prescription dose
Planning aim: what you want to obtain Prescribed dose: what you decide to treat
Case 6, IIIB, IC/IS BT
Appendix, ICRU 89 , PP201-207
Structure
Dose-volume parameter
Planning aim, Gy Prescribed dose Gy
CTV
EQD2
D
≥ 85
88.9
HR
10
90
3
Bladder
EQD2
D D
≤ 90 ≤ 70
71.1 65.6
3
2cm
3
Rectum EQD2 3
2cm
3
Sigmoid
EQD2
D
≤ 70
57.4
3
2cm
3
Bowel
EQD2
D
≤ 70
53.3
3
2cm
57