Dose response relationship for cardiovascular event and mean heart radiation dose (from EORTC randomized trials in HL)
Suggested constraints:
≤ 4 Gy: should be obtained in all but the most challenging cases
5-15 Gy: acceptable
> 15 Gy: consider omission or modification of plan
Maraldo MV et al. Lancet Haematol 2015; 2: e492-502