Particle Therapy 2017
0
not circumferenPal
Small Bowel: Dose / Volume distribution in 31 patientsxx treated to mean target doses of 72.3 Gy(RBE) (range: 64-76) Volume mean (cc) range (cc) V 5 (24 pts.) 86.5 2.0 - 238 V20 (24 pts.) 45.1 0.2 - 151 V30 (22 pts.) 35.5 0.1 - 120 V40 (20 pts.) 27.5 0.2 - 89.0 V50 (19 pts.) 17.7 0.2 - 59.0 V60 (17 pts.) 7.6 0.4 - 29.0 V70 (12 pts.) 2.4 0.1 - 11.0 Volume mean (cc) range (cc) V75 (10 pts.) 1.9 <0.1 - 3.1 V80 (4 pts.) 0.2 <0.1 - 0.5 Using the sharp dose fall-off, proton therapy can deliver high doses to posterior bowel walls, yet only moderate doses to anterior bowel walls
Results at PSI
(Schneider et al., 2010, ASTRO presentation)
Small bowel can tolerate well doses > 60 Gy(RBE), as long as
XX = volume definition and analysis based on initial planning CT
Made with FlippingBook Online document