Random Errors Only: M rand
=0.7 σ
The CTV experiences daily shifts of the dose distribution due to daily random variations in the position of the CTV If we add the daily shifted dose distributions the dose distribution appeares to be blurred (motion blurring) The effect of the random error can be calculated by convolving the random error distribution with the dose distribution => blurred dose distribution
⊗
=
random error σ