ESTRO 2024 - Abstract Book
S341
Beachytherapy - Physics
ESTRO 2024
[1] J. R. Hiatt, S. D. Davis, M. J. Rivard, A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model, Medical Physics 42 (6) (2015) 2764–2776. doi:10.1118/1.4919280. [2] M. Pinto, P. Gon calves, Guimesh: A tool to import step geometries into geant4 via gdml, Computer Physics Communications 239 (2019) 150–156, program Title: GUIMesh, Program Files doi: http://dx.doi.org/10.17632/c3c9xbspzp.1, Licensing provisions: GNU General Public License 3 (GPLv3), Programming language: Python. doi:10.1016/j.cpc.2019.01.024. [3] S. Agostinelli, et al., Geant4—a simulation toolkit, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 506 (3) (2003) 250–303. doi:10.1016/s0168-9002(03)01368-8. [4] D. S. A. Alvarez, P. G. F. Watson, M. Popovic, V. J. Heng, M. D. C. Evans, J. Seuntjens, Monte carlo calculation of the relative tg-43 dosimetry parameters for the intrabeam electronic brachytherapy source, Phys. Med. Biol. 66 (2021) 045026. doi:10.1088/1361-6560/abc6f1.
[5] S. M. Seltzer, M. O’Brien, M. G. Mitch, New national air-kerma standard for low-energy electronic brachytherapy sources, J. Res. Natl. Bur. Stand. 119(2014) 554–574. doi: 10.6028/jres.119.022.
[6] M. J. Rivard, B. M. Coursey, L. A. DeWerd, W. F. Hanson, M. S. Huq, G. S. Ibbott M. G. Mitch, R. Nath, J. F. Williamson, Update of AAPM task group no. 43 report: A revised AAPM protocol for brachytherapy dose calculations, Medical Physics 31 (3) (2004) 633–674. doi:10.1118/1.1646040.
URL https://doi-org.proxy3.library.mcgill.ca/10.1118/1.1646040427
[7] L. A. DeWerd, W. S. Culberson, J. A. Micka, S. J. Simiele, A modified dose calculation formalism for electronic brachytherapy sources, Brachytherapy 14 (3) (2015) 405–408. doi:10.1016/j.brachy.2015.01.003. URL https://doi.org/10.1016/j.brachy.2015.01.00
[8] J. Kalinowski, , G. Famulari, S.A. Enger, RapidBrachyTG43: A Geant4-Based TG-43 Parameter Calculation Engine for Brachytherapy Applications. PP24 Presentation Time: 4:10 PM. Brachytherapy, 20(3) (2021), S21-S22.
1043
Proffered Paper
External validation of automated treatment planning for HDR prostate brachytherapy using BRIGHT
Anders T Hansen 1 , Anton Bouter 2 , Peter A N Bosman 2 , Tanja Alderliesten 3 , Simon Buus 4 , Jacob G Johansen 5
1 Aarhus University Hospital, Medical Physics, Århus, Denmark. 2 2 Centrum Wiskunde & Informatica, Life Sciences and Health, Amsterdam, Netherlands. 3 Leiden University Medical Center, Department of Radiation Oncology, Leiden, Netherlands. 4 Aarhus University Hospital, Department of Oncology, Århus, Denmark. 5 Aarhus University Hospital, Danish Center for Particle Therapy, Århus, Denmark
Purpose/Objective: