Figure 1: Boxplot for the DVH-parameters for all treatment plans. Here manual denote the manual method; p-s – the pseudo-structures method and sf – the straightforward method.
Table 1. The distribution of the mean dwell times (± one standard deviation) in the different part of the implant for the three different treatment planning methods; manual, pseudo-structures and straightforward.
Conclusion:
We have shown that an automated planning method can be used to obtain treatment plans with a dwell distribution that fulfills the recommendations using the invented pseudo-structures. The automated treatment plans with pseudo-structures prioritize the target volumes higher than the OARs in comparison to the manual treatment plans.