ESTRO 2025 - Abstract Book
S3487
Physics - Optimisation, algorithms and applications for ion beam treatment planning
ESTRO 2025
Conclusion: Erasmus-iCycle can generate robust IMPT- and IMPT+TB plans automatically with similar or improved dosimetric metrics for target coverage, OARs and NTCPs, as compared to clinical manual planning. Incorporation of TB to IMPT enhanced dose reductions in serial OARs.
Keywords: Nasopharynx, Automated planning, Transmissionbeams
2125
Mini-Oral Pitfalls associated with composite plan evaluations of LETd can be reduced using a field-by-field approach Vadim P Moskvin 1 , Fakhriddin Pirlepesov 1 , Chris J Beltran 2 , Thomas E Merchant 1 1 Radiation Oncology, 1. St. Jude Children's Research Hospital, Memphis, USA. 2 Radiation Oncology, 2. Mayo Clinic, Jacksonville, USA
Made with FlippingBook Ebook Creator