ESTRO 36 Abstract Book
S461 ESTRO 36 2017 _______________________________________________________________________________________________
PO-0856 Systematic baseline shifts of lymph node targets between setup and treatment of lung cancer patients M.L. Schmidt 1 , L. Hoffmann 1 , M.M. Knap 2 , T.R. Rasmussen 3 , B.H. Folkersen 3 , D.S. Møller 1 , B. Helbo 2 , P.R. Poulsen 2 1 Aarhus University Hospital, Medical Physics, Aarhus C, Denmark 2 Aarhus University Hospital, Department of Oncology, Aarhus C, Denmark 3 Aarhus University Hospital, Department of Pulmonology, Aarhus C, Denmark Purpose or Objective Internal target motion results in geometrical uncertainties in lung cancer radiotherapy. The lymph node (LN) targets in the mediastinum are difficult to visualize in cone-beam computed tomography (CBCT) scans for image-guided radiotherapy, but implanted fiducial markers enable visualization on CBCT projections and fluoroscopic kV images. In this study, we determined the intrafraction motion of mediastinal LN targets in both the setup CBCT and fluoroscopic kV images acquired during treatment delivery, and investigated the baseline shifts and treatment accuracy of LNs for ten lung cancer patients. Material and Methods Ten lung cancer patients had 2-4 fiducial markers implanted in LN targets by EBUS bronchoscope. A total of 26 markers were evaluated. The patient received IMRT with daily setup CBCT for online soft tissue match on the primary tumor. During treatment delivery, 5 Hz fluoroscopic kV images were acquired orthogonal to the MV treatment beam. Offline, the marker positions were segmented in each CBCT projection and fluoroscopic kV image. From the segmented marker positions, the 3D marker trajectories were estimated from the segmentations with sample rate of 11 Hz during CBCT acquisition and 5 Hz during treatment delivery. The 3D motion amplitude and mean position of each LN marker as well as the intrafraction baseline shifts between setup CBCT and treatment delivery were calculated. Results Figure 1 shows the internal motion of one marker at one fraction. The motion is shown relative to the mean position during the CBCT scan and corrected for the couch shift between CBCT and treatment. For this marker, the baseline shift was 4.8 mm cranially, 0.6 mm posteriorly, and 0.7 mm towards right. Figure 2a shows the distribution of intrafraction baseline shifts for all patients and LNs at all fractions. Systematic LN baseline shifts occurred between CBCT and treatment delivery in the cranial direction (mean 2.4 mm (SD 1.9 mm)) and posterior direction (0.8 mm (1.1 mm)). The frequency of cranial baseline shifts exceeding 4 mm and 6 mm were 15 % and 4 %. The baseline shifts resulted in systematic mean geometrical errors during treatment delivery of 2.8 mm (cranial) and 1.4 mm (posterior)(Figure 2b) for the LNs. These errors were substantially larger than the sub- millimeter mean errors expected from the setup CBCT based soft tissue tumor match when correcting for the applied couch shifts. In general, the largest LN motion amplitude was observed in the cranio-caudal direction both during CBCT and treatment delivery. The mean motion amplitudes during CBCT and treatment delivery agreed within 0.2 mm in all three directions.
Conclusion Systematic cranial and posterior intrafraction baseline shifts between setup CBCT and treatment delivery occurred for mediastinal LN targets in lung cancer patients and reduced the treatment accuracy. Intrafraction motion amplitudes were stable throughout each treatment fraction, as well as the treatment course. PO-0857 Analysis of Intrafraction Motion in Image- Guided Stereotactic Radiosurgery of Spinal metastases J.G. Svestad 1 1 Oslo University Hospital The Norwegian Radium Hospital, Department of Medical Physics, Oslo, Norway Purpose or Objective Stereotactic radiosurgery of spinal metastases include tight margins and steep dose gradients to the surrounding organs at risk (OAR). The proximity of the target to the adjacent spinal cord and the aim of keeping the dose to the spinal cord within tolerance require a high degree of precision in dose delivery. This study aimed to evaluate intrafractional motion using cone beam computed tomography (CBCT) image guidance, for immobilized spinal stereotactic radiosurgery patients, with correction in all six degrees of freedom. Material and Methods Intrafractional motion during spine radiosurgery treatment in 16 patients (26 fractions) was retrospectively analyzed. All patients were immobilized in the BlueBAG BodyFIX (Elekta, Stockholm, Sweeden) that uses a vacuum pump to create a precise mold of the patient’s position. Radiation treatment was performed using a Varian Truebeam STx linear accelerator equipped with a PerfectPitch 6 degrees of freedom couch (Varian Medical Systems, Inc., Palo Alto, USA). Following initial setup, a CBCT was acquired for patient alignment and patient position was corrected in all six degrees of freedom. Patients were resetup manually, and the process was reinitiated if the ± 3˚ rotational couch tolerance was exceeded. A post treatment CBCT was
Made with FlippingBook