S462 ESTRO 36 2017 _______________________________________________________________________________________________
acquired and analyzed using the offline image review workspace in Mosaiq (v1.60, Elekta, Stockholm, Sweden) to determine intrafractional patient movements. From each CBCT, 3 translational and 3 rotational coordinates were obtained. Results The average time between the patient setup CBCT and the post treatment CBCT was 9 minutes (range, 6-14). The average absolute translational variations (± 1 SD) obtained from the post-treatment CBCT was 0.7 ± 0.7, 0.7 ± 0.8 and 0.5 ± 0.6 mm in the lateral, longitudinal and vertical directions, respectively. The average absolute rotational angles were 0.8 ± 0.7, 0.7 ± 0.4 and 0.8 ± 0.6˚ along pitch, roll and yaw, respectively. Histograms of translational and rotational deviations for all patients are shown in figure 1.
Image analysis: The two dynamic MR series were analyzed separately to quantify typical one minute tumor displacements along two orthogonal directions; superior (S), inferior (I), anterior (A) and posterior (P). All time- points affected by non-respiratory associated tongue motion or deglutition were manually discarded from the analysis. One time-point was selected as the reference and all other points were non-rigidly registered to the reference using a validated optical flow algorithm [1]. Motion fields were computed for all the pixels inside the tumor and combined into a single distance metric by assessing the maximum contour coordinates (FIG1-A+B). Typical 10-minutes displacements were investigated by computing the difference Results Mean maximum 1-minute tumor displacements amounted to 2.08 (SD 2.34) mm in (S), 2.26 (SD 1.48) mm in (I) and 1.66 (SD 0.93) mm in (A); 1.65 (SD 1.23) mm in (P) (FIG1- D). However, there was strong inter-subject variability within the laryngeal and oropharyngeal subgroups, with laryngeal tumors exhibiting periodic displacements up to 14 mm in (S) (FIG1-C). The typical 10 minute shifts were smaller than 2 mm for all patients (not shown in figure), with means values of 0.62 (SD 0.44) mm in (S) ; 0.64 (SD 0.58) mm in (I); 0.49 (SD 0.51) mm in (A); 0.41 (SD 0.36) Although tumor displacements were small, there were three subjects that exhibited resting-state displacements larger than 5 mm. This suggests individualized ITVs for the laryngeal tumors and oropharyngeal tumors, instead of applying 5 mm margins in both I and S directions for laryngeal tumors. The 10-minutes intrafraction shift was smaller than 2 mm across all the patients and directions and did not show any outliers. mm in (P). Conclusion
Conclusion Near-rigid body immobilization, CBCT image guidance and six degrees of freedom correction yields minimal intrafractional motion and safe stereotactic spine radiosurgery delivery. It is not easy to determine the effect of rotational deviations. However, for treatment plans with the isocenter plased in the center of the target volume, which is the case for these patients, small rotations would not result in large deviations in dose to the target volume or adjacent OARs. There are different approaches that could result in less patient motion and increased precision in dose delivery. The combination of a polyethylene sheet with a vacuum cushion would presumably result in a more rigid immobilization. Intrafractional imaging during treatment is another alternative that could increase precision in dose delivery. PO-0858 Intra-fraction motion quantification of head- and-neck tumors using dynamic MRI T. Bruijnen 1 , R.H.N. Tijssen 1 , M.E.P. Philippens 1 , C.H.J. Terhaard 1 , T. Schakel 1 , J.J.W. Lagendijk 1 , C.P.J. Raaijmakers 1 , B. Stemkens 1 1 UMC Utrecht, Radiotherapy, Utrecht, The Netherlands Purpose or Objective Previous research primarily focused on the effect of deglutition on the accumulated tumor do se. However, resting-state movements, such as respiratory-induced tumor motion, has been largely overlooked. Nonetheless, this may play an important role in the size of the treatment volume of head-and-neck cancer. Here, we investigate head-and-neck resting-state tumor motion in a radiotherapy treatment position in order to provide guidance for adequate internal target volume (ITV) determination. Material and Methods Acquisition: 46 patients with head-and-neck cancer (6 nasopharyngeal/ 25 oropharyngeal/ 15 laryngeal) underwent pretreatment clinical MRI scanning in a radiotherapy treatment setup, including a custom-fit immobilization mask. Two 2D sagittal dynamic acquisitions (RF- and gradient-spoiled gradient echo; TE/TR=1.5/3ms; voxel size=1.42x1.42x10 mm 3 ;158 ms temporal resolution), separated 10 minutes apart, localized to intersect the tumor were acquired on a 3.0T scanner. GTV delineations, as performed by a radiation oncologist, were obtained from the treatment plans.
PO-0859 Impact of 4DCBCT reconstruction algorithm and surrogate on motion representation E. Steiner 1 , C.C. Shieh 1 , V. Caillet 2 , N. Hardcastle 2 , C. Haddad 2 , T. Eade 2 , J. Booth 2 , P. Keall 1 1 University of Sydney, Radiation Physics Laboratory- Sydney Medical School, Camperdown, Australia 2 Northern Sydney Cancer Centre- Royal North Shore Hospital, Radiotherapy Department, St Leonards, Australia Purpose or Objective Lung tumour motion exceeding the observed motion from planning 4D computed tomography (4DCT) is of concern in stereotactic ablative body radiation therapy (SABR). 4D cone-beam CT (4DCBCT) facilitates verification of tumour trajectories before each treatment fraction and an accurate patient setup. This work aims to assess the impact of the selection of the reconstruction algorithm and surrogate for binning on the motion representation in
Made with FlippingBook