the 4DCBCTs using implanted Calypso beacons in the lung as ground truth. Material and Methods 4DCBCTs were reconstructed from projections for treatment setup CBCT for 1-2 fractions of 6 patients using the prior image constrained compressed sensing (PICCS) method and the FDK (Feldkamp-Davis-Kress) method. For both methods reconstructions were performed based on the internal Calypso motion trajectories (three beacons per patient) or an external respiratory signal (Philips Bellows belt). The Calypso beacons were segmented for all 10 bins of the 4DCBCTs and the beacon centroid motion compared to the motion range from the images. Paired t- tests were performed on the mean size of excess beacon motion and the proportion of scanning time with motion larger than represented in 4DCBCT in order to identify a superior reconstruction method. Results All methods for 4DCBCT reconstruction failed to capture sudden motion peaks during scanning and underestimated the actual beacon centroid motion (see Fig. 1), which is a result of phase-based binning and averaging the images in a bin. For the SI direction in general, reconstructions using the belt signal, led to a representation of a larger motion range (PICCS: 4.88±3.30mm, FDK: 4.81±3.35mm) than the Calypso-based reconstruction (PICCS: 4.71±3.22mm, FDK: 4.76±3.29mm). However, the difference was not significant, as for none of the other directions. For comparison also the Calypso motion during the treatment exceeding the 4DCBCT motion range is shown in Figure 1.
Stereotactic body radiotherapy (SBRT) for prostate is a cost-effective treatment option with improved patient comfort and maintained excellent clinical outcomes. However, to ensure low levels of toxicity very accurate delivery is imperative, especially when combined with integrated focal boosts as in the Hypo-FLAME clinical trial methodology. Within this context, intra-fraction organ motion management becomes even more relevant. The novel BioXmark® (Nanovi A/S) biodegradable radio- opaque liquid fiducial marker was studied as alternative for current markers used in prostate motion management. The marker can be injected with very thin needles (down to 25G) and the injection procedure allows to vary the marker-size by altering the injected volume. In this study the automatic detectability of BioXmark® in 2D kV X-ray imaging was determined. Additionally, as Hypo-FLAME involves a multi-modality delineation of the boost foci, visibility/artefacts in different types of volumetric imaging was investigated. Material and Methods BioXmark® consists of sucrose acetate isobutyrate (SAIB), iodinated-SAIB and ethanol solution. Upon injection, ethanol diffusion out of the solution causes a viscosity increase and formation of a gel-like marker. A total of 8 markers (size 5-300 µL) organized in a rectangular grid were injected into a gelatin phantom. X-ray projection images using the Varian TrueBeam STx OBI were obtained by putting the gelatin phantom on top of an anthropomorphic pelvic phantom. A total of 120 images of each marker were acquired varying the positions of the marker relative to pelvic bony structures and using 24 clinically relevant X-ray kVp/mAs settings. Volumetric imaging was performed with CT, CBCT and MRI using a CIRS pelvic phantom. Automated marker detection was based on the normalized cross-correlation (NCC) of the projection image with a marker template retrieved from the CT image. Prior to detection, single markers were artificially isolated to minimize interference between detection of the different markers. Reference marker positions were manually determined on the image with highest exposure settings. A detection was successful if the optimal NCC value lied within a 1 mm (3 pixels) tolerance of the reference position. The tolerance was extended to 4 pixels to deal with the uncertainty of manual delineation. Results Detection success rates augmented with increasing marker-size obtaining a maximum for intermediate size (25-75 µL) markers (Figure 1). Larger marker sizes (>75 µL) had decreased detection success rates due to higher susceptibility for interference with the bony structure edges. Volumetric image artefacts were minimal whilst the markers itself were clearly visible (Figure 2). Conclusion Intermediate size (25-75 µL) BioXmark® liquid fiducial markers showed high detectability and minimal image artefacts making them a patient friendly alternative (thin needles) for the current markers used in fiducial-marker- based intra-fraction organ motion monitoring in prostate SBRT.
Figure 1. Proportion of intra-CBCT (solid lines) and intra- treatment (dashed lines) motion in SI direction larger than the motion represented in the reconstructed 4DCBCT for reconstruction with a) PICCS Belt, b) PICCS Calypso, c) FDK Belt and d) FDK Calypso. Conclusion All 4DCBCT reconstruction methods failed to rep resent the full tumour motion range , but performed similar. Thus, the belt as an external surrogate is sufficient for 4DCBCT reconstruction. For a safe treatment in spite of motion exceeding the motion range from the images, adequate ITV-to-PTV margins or a real-time treatment adaptation directly tackling motion peaks and unpredictable motion need to be chosen. While the 4DCBCT is not able to capture and predict the whole motion range of a treatment fraction, it serves as a valuable tool for accurate patient setup. PO-0860 Characterization of a novel liquid fiducial marker for organ motion monitoring in prostate SBRT R. De Roover 1 , W. Crijns 2 , K. Poels 2 , R. Peeters 3 , K. Haustermans 1,2 , T. Depuydt 1,2 1 KU Leuven - University of Leuven, Department of Oncology, Leuven, Belgium 2 University Hospitals Leuven, Department of Radiation Oncology, Leuven, Belgium 3 University Hospitals Leuven, Department of Radiology, Leuven, Belgium
Purpose or Objective
Made with FlippingBook