Results From the simulation of patient weight loss (thickness reduction), Watchdog has less sensitivity to small patient thickness reduction. From figure 1 left, it can imply that dropping by 25% c pass-rate refers to 10% patient thickness reduction or approximately 1.5 cm shrinkage. In clinical case validation, Watchdog was able to detect the significant patient anatomical changes that lead to the decision to replan all four HN IMRT patients (see figure 1 right). Based on this study, we found that Watchdog system can detect the clinically significant anatomical change in HN IMRT based on 1) at least 3 out of 7 fields of the fraction are below the SPC-based threshold, 2) the lowest c pass-rate is less than 30%, and 3) a 25% c pass- rate drop equates to approximately a 1.5 cm (-10.0%) patient thickness reduction. Conclusion The Watchdog dosimetic response to HN patient anatomical changes has been evaluated based on the simulation of patient thickness reduction/weight loss and clinical cases of HN IMRT replan. Using the SPC-based threshold, Watchdog is able to detect clinically significant anatomical changes in HN IMRT treatment.
(∆R o ) was determined at the distal and proximal edge of the tumor respectively. Secondly, for each angle and patient, the 90th percentile of ∆R u and ∆R o were calculated. Finally, median and inter-quartile ranges for these beam-specific range uncertainties were evaluated. Results Figure 1 shows the median and inter-quartile range of ∆R u and ∆R o for the 13 different angles. For both ∆R u and ∆R o, the range errors of the lateral beams (around 90 ⁰ ) are significant lower (paired T-test, p < 0.05) than the anterior and posterior beams. Moreover, there is considerable inter-patient differences in range uncertainties.
Figure 1. Median and inter-quartile range of the range error ∆R in overshoot and undershoot at the beam’s proximal and distal edge of the tumor respectively. The angle of 90 ⁰ is the lateral beam to the ipsilateral lung. Conclusion Variation in anatomy during the course of irradiation causes variation in range, possibly leading to tumor under- coverage and high dose in normal tissue. These range uncertainties depend on patient and beam angle, and are smaller for the lateral beams. Taking these beam-specific range uncertainties into account, could improve the robustness of proton treatment plan against anatomical variations. PO-0870 DIBH produces a meaningful reduction in lung dose for some women with right-sided breast cancer J.L. Conway 1 , L. Conroy 1 , L. Harper 1 , M. Scheifele 1 , W. Smith 1 , T. Graham 1 , T. Phan 1 , H. Li 1 , I.A. Olivotto 1 1 Tom Baker Cancer Centre, Radiation Oncology, Calgary- Alberta, Canada Purpose or Objective To determine whether deep inspiration breath hold (DIBH) produced a clinically meaningful reduction in pulmonary dose in comparison to free breathing (FB) during adjuvant loco-regional radiation (RT) for right-sided breast cancer. Subsequently, to prospectively evaluate DIBH in right- sided breast cancer cases with a FB V20Gy ≥30%. Material and Methods Thirty consecutive women with breast cancer treated with tangent pair RT following breast conserving surgery were included. ESTRO guidelines were used to contour right- sided IMC nodes on DIBH and FB scans, with care taken to ensure comparability between scans. A four-field, modified-wide tangent plan was developed on each scan to include the right breast and full regional nodes with a minimum dose of 80% to the IMC CTV. The junction between the supraclavicular and tangent fields was at the inferior extent of the ossified medial clavicle. Treatment plans were calculated in Eclipse using Acuros algorithm version 11. FB and DIBH plan metrics were compared using Wilcoxon-signed rank testing. Commencing in March 2016, as per a new institutional policy based on the above results, all right-sided breast cancer patients with a FB ipsilateral lung V20 ≥30% had a DIBH treatment plan developed prior to compromising on IMC coverage. If the absolute difference in lung V20 was ≥5% between plans, the DIBH plan was used. The junction was moved superiorly in only one case. Results
PO-0869 A population-based estimate of proton beam specific range uncertainties in the thorax Y.Z. Szeto 1 , M.G. Witte 1 , M. Van Herk 2 , J. Sonke 1 1 Netherlands Cancer Institute Antoni van Leeuwenhoek Hospital, Radiotherapy department, Amsterdam, The Netherlands 2 Institute of Cancer Sciences- University of Manchester, Molecular and Clinical Cancer Sciences, Manchester, United Kingdom Purpose or Objective Proton therapy has great potential for locally advanced lung cancer patients because of considerable reduction of intermediate and low dose to the healthy tissues. However, due to their finite beam range, proton dose distributions are more susceptible to anatomical variations. The purpose of this study was to derive a population-based map of beam specific range uncertainties due to anatomical variations. Material and Methods The planning CT (pCT) of 100 NSCLC patients treated between 2010 and 2013 with (chemo-)radiotherapy were included. To simulate realistic anatomical variations, we used a previously developed statistical model, based on principal component analysis for systematic variations in the thorax. This model generates deformation vector fields that deform the planning CT to induce systematic differences between the anatomy of planning and delivery. For each patient, we synthesized 1000 CTs (sCT) representing plausible variations in treatment anatomy. Subsequently, the water-equivalent path length differences (∆R) between the pCT and sCTs was calculated at the beam’s distal and proximal edge of the GTV for 13 equally spaced angles of 15 ⁰ through the ipsilateral lung. Undershoot and overshoot at the distal edge results in an under-coverage of the target and higher dose in normal tissues respectively, and vice versa at the proximal edge. To summarize the results, first for each scan and angle, the 95th percentile ∆R in undershoot (∆R u ) and overshoot
Made with FlippingBook