ESTRO 36 Abstract Book
S470 ESTRO 36 2017 _______________________________________________________________________________________________
IMC coverage was equivalent between DIBH and FB plans (Table 1). Twenty-one patients (70%) had ≥5% reduction in ipsilateral lung V20 with DIBH (Figure 1). A reduction in lung metrics was observed with an absolute reduction in mean ipsilateral lung V20 by 7.8% (range: 0.0-20.0%; Table 1). There was a mean reduction of 42.3cc (range: 0-178.9) in the volume of liver receiving 50% of the prescription dose. The differences in cardiac doses were statistically significant, but unlikely clinically significant (Table 1). Seven patients with stages IA-IIIC right-sided breast cancer treated between April to October 2016 received a DIBH scan as a result of a FB V20Gy ≥30%, treatment volumes included IMCs in all cases. In this cohort a ≥5% difference between plans was observed for all patients with a mean FB V20 of 34.8% (range: 30.0-43.4%), which was reduced by an absolute value of 11.8% (range: 5.4-19.1%) with DIBH.
To analyze the effects of considering the real distribution of random errors (s) within our patient population in the outcome of setup correction protocols. Results are compared to those predicted by Van Herk`s margin formula (VHMF) considering constant random errors. Material and Methods Displacement data from 31 prostate and 31 head and neck (HN) treatments were employed in this study, based on 640 and 540 CBCT images respectively. Values of σ at each direction were calculated by obtaining the standard deviation of the corrections during the treatment of each patient. The proposed distribution for the modelling of heterogeneous σ 2 is an IG distribution (eq. 1). This kind of distribution has been demonstrated to be suitable for modelling random errors (Herschtal et al, Phys Med Biol 2012:57:2743-2755). Parameters a and b of the IG distribution can be obtained from the mean value and standard deviation of the measured σ 2 distribution. Treatment margins proposed by VHMF for a No Action Level using the first 5 fractions for setup correction (NAL 5) protocol were obtained by considering a constant σ for all the patients. Given the margins proposed, the patient coverage for the real σ distribution was obtained by weighting the dose coverages for each combination of σ values at each direction with the probability that a patient has those values of σ, based on the fitted IG distributions. Results Results are shown in Table 1. It can be seen that, if heterogeneities in random error distribution are taken into account, the coverage probability yields values smaller than those predicted by VHMF when homogenous σ is considered. After this results were obtained, calculations for different sets of margin were done. It was found that in the HN case, margins had to be increased 1 mm at each direction to obtain coverages of a 92 %, while in the prostate case, margins had to be increased 1.4 mm in all directions in order to achieve a coverage of the 90%. These results suggest that the effects of heterogeneous random errors depend on the characteristics of the random error distribution of the patient population. Conclusion The effect of heterogeneous random errors should be taken into account when applying treatment margins, its effects depend on the characteristics of the patient population and should be analyzed for each treatment location at each institution. PO-0872 Respiration motion management strategy for sparing of risk organs in esophagus cancer radiotherapy S.B.N. Biancardo 1 , J.C. Costa 1 , K.F. Hofland 1,2 , T.S. Johansen 1 , M. Josipovic 1 1 Rigshospitalet, Department of Oncology- Section of Radiotherapy, Copenhagen, Denmark 2 Zealand University Hosptial, Department of Oncology- Section of Radiotherapy, Naestved, Denmark Purpose or Objective Esophagus and the organs at risk (OAR) nearby move with respiration. The purpose of this study was to determine if
Conclusion DIBH reduced mean ipsilateral lung V20 by 7.8% and mean lung dose by 3.4Gy. For some patients, the volume of liver receiving ≥25Gy can also be reduced with DIBH. DIBH should be available as a treatment strategy to reduce right lung V20 without compromising on IMC coverage for patients with right-sided breast cancer during loco- regional RT. This strategy can be advantageous when the ipsilateral FB V20 ≥30%, a value that prompts many radiation oncologists to exclude IMCs. Within a small prospectively evaluated cohort reflective of a change in institutional policy, we have observed an absolute reduction in mean ipsilateral lung V20 by 11.8% with DIBH. PO-0871 Study of the effect of heterogeneous setup random errors in treatment margins D. Sevillano 1 , A.B. Capuz Suárez 1 , R. Colmenares Fernández 1 , R. Morís Pablos 1 , M.J. Bejar Navarro 1 , D. Prieto Moran 1 , F. García-Vicente 1 1 Hospital Ramón y Cajal, Medical Physics, Madrid, Spain
Purpose or Objective
Made with FlippingBook