respiratory gating or deep inspiration breath hold (DIBH) facilitate dose reduction to OAR. Material and Methods CT image sets from ten patients were analysed. Esophagus and OAR were delineated on end expiration (EE) and end inspiration (EI) phases of the 4DCT and on DIBH CT. 5 cm long mock GTVs were delineated in the proximal (P), medial (M) and distal (D) part of the esophagus. CTVs were defined by expanding the GTVs according to our clinical practice. CTV to PTV margin was 7 mm. Relative position of OARs and target were evaluated with cumulative distance volume histograms (DiVHs) [Wu et al. Med Phys 2009], calculated for the part of the OAR located in the beam path. The most and least optimal phase for treatment was selected by comparing the percent of the OAR volume located within the distance intervals A (below 2.5 cm), B (2.5-5.0 cm) and C (5.0-7.5 cm) from the PTV. The organ sparing achieved or lost, by changing treatment from FB to a specific breathing phase, was estimated by assuming that FB can be simulated with 50% EE and 50% EI. Results Esophagus elongation during 4DCT was median 11mm (range 2-20mm) and from EE to DIBH 23mm (10-42mm). Lung volume increased 13.3% (6.9-24.9%) from EE to EI and 63.5% (34.1-120.8%) from EE to DIBH. Absolute volume of lung in the beam path either increased or remained largely constant upon inspiration in all patients. In seven P, four M and four D targets, the absolute volume of lung located within 5 cm of the PTV increased; however, increase in the total lung volume still resulted in either a reduction or a largely unchanged percent lung volume located within 5 cm of the PTV. Results extracted from DiVHs are presented in Table 1.

Liver had median displacement of 12mm on 4DCT and 43mm from EE to DIBH. It was only in the beam path for D targets. Even though volume in the beam path decreased with median 1.1% (EI) and 2.6% (DIBH) compared to EE, EE was still optimal in 2 and DIBH only optimal in 5 patients. Conclusion Lung sparing can be achieved in DIBH for proximal, medial and most distal esophagus targets. For some medial and distal targets heart sparing can be achieved. As the optimal phase is not always DIBH, lung vs. heart sparing must be prioritized. No general conclusions can be drawn for liver. Further investigations are warranted. PO-0873 Inter- and intra-fraction motion of the tumor bed and organs at risk during IGRT for Wilms' tumor F. Guerreiro 1 , E. Seravalli 1 , G. Jansses 1,2 , M. Heuvel- Eibrink 2 , B. Raaymakers 1 1 UMC Utrecht, Department of Radiotherapy and Imaging Division, Utrecht, The Netherlands 2 Princess Máxima Center, Pediatric Oncology/Hematology, Utrecht, The Netherlands Purpose or Objective Radiotherapy planning for Wilms' tumor (WT) is currently done according to the SIOP-2001 protocol. The planning target volume (PTV) is defined as the clinical target volume (CTV) plus a margin of 10-mm while no planning risk volume (PRV) margins are recommended. The aim of this study is to assess inter- and intra-fraction motion of the tumor bed and organs at risk (OARs) as well as patient positioning uncertainty to estimate PTV and PRV margins for flank irradiation in WT. Material and Methods Computed tomography (CT), 4D-CT and daily cone-beam CTs (CBCTs), acquired during planning and treatment of 10 pediatric patients (mean 3.9 ± 2.1 years) were used. OARs (kidney, liver and spleen) were delineated without accounting for any motion in all image sets. OARs motion was quantified in terms of absolute displacements of the center of mass (CoM) in all orthogonal directions. Tumor bed motion estimation was assessed using a quadratic sum of the CoM displacements of 4 clips positioned at the superior, lateral, medial, and inferior border of the tumor during surgical resection. Intra-fraction motion was estimated by calculating the CoM displacements between the maximum inspiration and expiration phases of the 4D- CT. For inter-fraction motion assessment, CoM displacements were calculated using the planning-CT as reference and daily pre-treatment CBCTs. For intra-fraction patient positioning uncertainty, translational and rotational bone off-sets between the

DIBH was the optimal treatment phase for all P and M targets and 8/10 D targets. For all targets EE was the least optimal phase. Heart displacement was ≤12mm on 4DCT and ≤26mm from EE to DIBH. Relative heart volume DiVH’s are shown in Figure 1 for 3 patients. The same respiration phase is clearly not optimal for all patients, neither for M nor for D targets. EE was most optimal for heart sparing in two M and three D, EI in four M and three D and DIBH in four M and four D targets. EE was least optimal in four M and two D, EI in two M and three D and DIBH in four M and five D targets.

Made with