planning-CT and post-treatment CBCTs were recorded. Inter-fraction patient positioning uncertainty was null as online patient position correction was always performed. Margins were determined by combining systematic (Σ) and random (σ) errors. Van Herk (2.5∑ + 1.7σ) and McKenzie (1.3∑ ± 0.5σ) analytic solutions were used for PTV and PRV margin expansions, respectively. Results Tumor bed and OARs mean CoM displacements were less than 3-mm for all directions for both inter- and intra- fraction motion. Largest displacements were seen in the cranio-caudal (CC) direction (Figure 1). Inter-fraction motion was larger than intra-fraction motion (Figure 1). Mean intra-fraction patient positioning uncertainty was considered negligible (translation <1-mm; rotation <1 o ). Σ and σ errors differed less than 2.5-mm for organ motion and 0.5-mm for patient positioning uncertainty. The calculated PTV and PRV margins (Table 1) were up to a maximum of 6/5-mm in the CC direction, respectively.

GTV position. Purpose of this study is to investigate the impact of a varying rectum filling on tumor position and quantify potential tumor shifts. Material and Methods For the analysis, nine patients were included who were scanned twice on MRI in supine position. First on a 1.5 T MRI for diagnostic purposes and next on a 3T MRI for treatment planning. For the diagnostic MRI, the rectum was filled using an ultra sound transducer gel (MRI full ), and for the planning MRI no rectal preparation was performed (MRI standard ). On both MRIs the tumor was delineated. To evaluate tumor displacement, for both MRI standard and MRI full , three distances in cranial-caudal (CC) direction were determined between the bony anatomy; i.e. the sacrum promontory and the tumor cranial border, the tumor caudal border and the center of mass (COM), (figure 1, C & D). For each distance measure, displacements were then determined by taking the difference in distance between both MRI scans. Results In all patients a shift in tumor COM in CC direction was observed, ranging between 6.9 and 28.3 mm. Mean tumor displacements between MRI standard and MRI full were found to be 16.7 mm, 16.5 mm and 17.7 mm for the cranial and caudal tumor border and the COM, respectively (figure 1 C & D). Displacements were all found to be significantly different from zero (p<0.002 for all distance measures). Displacement was larger for tumors situated higher up in the rectum (figure 2). Conclusion In all patients, tumor position changes considerably under influence of rectal filling. The found mean displacements are larger than the typical PTV-margins for rectal GTV (Brierley et. al 2011). The higher situated rectal tumors show the largest displacements under influence of rectal filling. To avoid geometrical miss of the tumor, rectal volume preparation prior to boost radiotherapy or adaptive RT with online tumor visualization using MRI (Lagendijk et al. 2008) seems beneficial. Especially for tumors located high in the rectum.

Conclusion Imaging data collected before and during radiotherapy demonstrated limited motion of the tumor bed and OARs and reduced patient positioning uncertainty. By combining 4D-CT and daily CBCTs information, PTV margins can be reduced to 6-mm in the CC direction compared with the existing protocol. The use of PRV margins for OARs protection is also advised. In addition, margins should be applied anisotropically and individualized for each patient. PO-0874 The impact of rectal filing on rectal tumor position J.J.E. Kleijnen 1 , M. Intven 1 , B. Van Asselen 1 , A.M. Couwenberg 1 , J.J.W. Lagendijk 1 , B.W. Raaymakers 1 1 UMC Utrecht, Radiotherapy department, Utrecht, The Netherlands Purpose or Objective In 15% of rectal cancer patients, a pathological complete response (pCR) is observed after neo-adjuvant chemoradiotherapy. To increase this pCR rate, many studies are being performed, in which the GTV dose is escalated. To avoid an increase in toxicity and potential surgical complications, PTV margins must be minimized and geometrical miss has to be avoided. However, rectal filling can change from day-to-day as can be observed in daily practice (see figure 1, A & B), which might alter the

Made with