medium phantom using TLD-100 and radiochromic EBT3 film. Material and Methods In-house wax phantom was constructed and drilled carefully to hold titanium tandem and ring applicator. To mimic the cervix brachytherapy, various materials which density equivalent to bladder, rectum, spongy bone and cortex bone were inserted. Moreover, inside the phantom was placed a cap for contained TLD to measure absorbed dose. Total of eleven TLD-100 points were selected, seven interested points which deposition in homogeneous region are represent the point dose for front of bladder, rectum, cortex bone as well as spongy bone, 1 cm from tip end of the tandem, right and left point A. Heterogeneous region contained four TLD measuring points as backside of bladder, rectum, cortex bone and spongy bone. After that the phantom was underwent CT scan with pelvic exposure protocol, and generated the pear-shape dose distribution with 10 Gy prescription dose at point A on BrachyVision TM treatment planning system(TPS) version 13.6 using either of TG-43 and Acuros TM BV algorithms. Then, the absorbed doses at all chosen points were measured by the TLDs, and radiochormic film EBT3 model was used to measure dose distribution. Results In this experiment, the variation of TLD measurements presented within 3% of standard deviation. Percentage of dose different between TG-43 and TLD measurements were found in the range of 7.58% to -21.21%, and -1.26% to 6.61% for Acuros TM BV. In homogeneous medium, dose calculation algorithm based-on TG-43 and Acuros TM BV presented the accurate dosimetric results with the dose different less than 4% when compared to the TLD. However, measuring point in the heterogeneous as behind the cortical bone showed the maximum dose different at -21.21% in TG-43, and was decreased to be 6.61% with Acuros TM BV. About the gamma evaluation with criteria of 3% dose difference and 3mm DTA as well as 10% threshold, the data showed the gamma passing rate at 97.3% for TG-43, and 98.3% for Acuros TM BV when compared to film measurement. Conclusion This investigation showed the accurate dosimetric results from both of TPS dose calculation algorithms in homogeneous region. However, heterogeneity correction algorithm as Varian Acuros TM BV showed significantly improve the accuracy of TPS dose calculation in heterogeneous medium when compared with the measurement. EP-2245 Precision IORT – Dosimetric and geometric evaluation of 10 Kypho-IORTs F. Schneider 1 , K. Steinbach 2 , F. Bludau 2 , S. Clausen 1 , F. Giordano 1 , F. Wenz 1 , U. Obertacke 2 , Y. Abo-Madyan 1 1 University Medical Center Mannheim, Department of Radiation Oncology, Mannheim, Germany 2 University Medical Center Mannheim, Department for Orthopaedics and Trauma Surgery, Mannheim, Germany Purpose or Objective Kypho-IORT is a treatment option for patients with spinal column metastases in which a minimally invasive surgical stabilisation of the vertebra (kyphoplasty) is combined with a sterilising dose of intraoperative radiation therapy (IORT).[1] This technique is geometrically limited by the trajectory through the pedicel to the metastasis inside the vertebra the surgeon can use to insert the kyphoplasty equipment and the needle applicator for IORT. It is dosimetrically limited by the dose to the spinal cord. Because of the lack of a treatment planning system (TPS) taking tissue heterogeneities into account, table based water prescription dose and depth were escalated in a clinical trial. [2]

In this study a new Monte Carlo based TPS was retrospectively used to geometrically and dosimetrically evaluate 10 patients treated with Kypho-IORT with its aim to individualize this kind of treatment. Material and Methods 10 patients underwent standard Kypho-IORT in vertebrae ranging from Th8 – L5 using the Intrabeam system including a dedicated Needle Applicator (Carl Zeiss Meditec AG, Jena, Germany). To measure the distance from applicator tip to the spinal canal intraoperative cone beam CTs (CBCT) using Artis Zeego (Siemens, Erlangen, Germany) were performed with the applicator in place. Post-operatively these CBCTs including each contoured applicator tip were registered with preoperative CTs including the contoured spinal canal and the metastasis as described in Schneider et. al. [3] Dose calculations were performed in Radiance (GMV, Madrid, Spain) using a hybrid Monte Carlo algorithm simulating dose in heterogeneous tissue. Geometrically the difference between applicator tip and center of each metastasis was evaluated. Dosimetrically the 8Gy coverage of each metastasis and the maximum dose to the spinal canal were evaluated. Results The geometrical distance from the tip of the applicator to the ideal center of the metastases, ranging from 1.14cm³ to 17.84cm³ in size, was 6.4mm in average (2.4mm – 13.1mm). Dosimetrically 44.9% - 99.9% of the metastases were covered with 8Gy. The maximum dose to the spinal canal was within 1.5Gy and 7.2Gy. Conclusion Because of the high attenuation in the cortical bone the maximum dose to the spinal canal was less than expected. The 8Gy coverage is rather driven by the applicator position than the size of the metastasis. So a pre-operative treatment planning followed by an image guided surgery might help defining the trajectory and to optimize the treatment. 1. Wenz, F., et al., Kypho-IORT--a novel approach of intraoperative radiotherapy during kyphoplasty for vertebral metastases. Radiat Oncol, 2010. 5: p. 11. 2. Bludau, F., et al., Phase I/II trial of combined kyphoplasty and intraoperative radiotherapy in spinal metastases. Spine J, 2017. 3. Schneider, F., et al., Precision IORT - Image guided intraoperative radiation therapy (igIORT) using online treatment planning including tissue heterogeneity correction. Phys Med, 2017. 37: p. 82-87. EP-2246 Generating and navigating a multi-criteria trade-off surface in high dose-rate brachytherapy C. Deufel 1 , V. Wu 2 , M. Epelman 2 , M. Sir 3 , K. Pasupathy 3 , M. Herman 1 1 Mayo Clinic MN, Radiation Oncology, Rochester, USA 2 University of Michigan, Department of Industrial and Operations Engineering, Ann Arbor, USA 3 Mayo Clinic MN, Health Sciences Research, Rochester, USA Purpose or Objective A method for generating and navigating the full range of dosimetric trade-offs between the target(s) and healthy tissue(s) in a high dose-rate (HDR) brachytherapy treatment is presented. This approach aims to improve HDR treatment planning efficiency and quality. Material and Methods The method generates a multi-criteria trade-off surface from an extensive library of high-quality HDR candidate plans, each obtained by solving an instance of a constrained optimization. Triangulation is further used to fill-in the surface between optimized plans by interpolating the dwell times of relevant library plans in each region. The trade-off surface is navigated with a

Made with FlippingBook - Online magazine maker