Physics Bucharest 2017
Clinical studies
Study (year)
n
Dose
Adaptive strategy Target coverage Normal tissue sparing
55Gy in 20f (bladder) (40Gy in 20f pelvis) or 60Gy in 25f (tumour, 6 patients)
3DCRT composite from week 3, for 10-25f
Pos et al., (2006)
5% repeat CT scan GTV not covered by PTV
40% reduction in PTV
21
185cm 3 high dose volume reduction (plan of the day) and 220cm 3 (composite) compared to conventional margin approach Bowel V45Gy improved by 155cm 3 compared to conventional margin 210cm 3 volume reduction in tissue receiving 95% dose compared to conventional margin approach
3DCRT 3 phase sequential delivery (adaptive phase 3 plan of the day or composite) IMRT 2 phase sequential delivery Plan of the day, phase 1, 3-4 plans; phase 2, 2-4 plans
Huddart et al., (2011)
64-68Gy in 32-34f (tumour) 50Gy in 25f (bladder)
*V95 98% (plan of the day), 91% (composite)
26
45-50.4 Gy in 25-28f (bladder) followed by 10-20Gy in 5-10f (tumour)
Tuomikoski et al., (2011)
V95<100% 3% (4/121 fractions)
5
McDonald et al., (2011)
3DCRT Plan of the day, 3 plans
25
36Gy in 6f (bladder)
*V95 99%
49